Laboratory Equipment (Used) : AVAILABLE TO SELL
Location: USA, BOSTON MA
Agilent 1100 system with G1321A FLD Detector.
HP or Agilent 1100 HPLC systems and our refurbishing process. All of our HPLC systems are refurbished by our Agilent Certified technician’s using OEM parts and then we do a 4 peak standard injection to make sure peak shape and retention times are spot on.
Agilent 1100 Series: HPLC System “Recertified To Factory Setting with OEM Parts”
Supplied with:
• G1321A FLD Detector
• G1316A Thermostated Column Oven
• G1322A Vacuum Degasser
• G1312A Binary Pump (Quat Pumps available)
• G1313A Autosampler
• PC (Windows XP)
• 32 Bit Chemstation (preloaded on PC)
• Solvent Tray
• LCD Monitor
• All Required Power and Communication Cables
• Operator’s Guide
• New Tubing, Gaskets, Valves & Flanges
***Analytical and Semi-Prep Configurations Available***
All our equipment is expertly reconditioned and then tested to perform at factory specifications before being shipped. The turnaround time is about 15 business days from receipt of a purchase order and payment terms need to be discussed.
HPLC Refurbishing Process
Main frame:
· All circuit boards, motors, and power supply are cleaned and inspected for proper operation, replaced as needed.
· Tubing is inspected and replaced as needed.
· All valves are disassembled, cleaned and inspected, rebuilt if necessary.
· Firmware is upgraded to support Workstation Provided
Pumping System:
· Pumps have been disassembled and inspected for proper operation.
· Wash seals, pump seals have been replaced.
· Plungers are inspected and replaced as needed.
· New inline filter is replaced. Inlet and outlet check valves are replaced Or rebuilt.
· Proportioning valves inspected for proper distribution and Replaced if necessary ( Multiple solvent Only)
· Transducers have been calibrated.
· High pressure leak tests performed and passed.
Injector, Sampler:
· Injector assembly is disassembled and cleaned.
· Needle, Injection seals, wash seals and frit are replaced
· Calibration for needle and seal alignment is performed.
· Heater/Chiller (Option) is cleaned and inspected and passed min/max temp test
· New syringe installed and tested
Performance: HPLC grade solvents are used at all times. Machine is run using an industry 4 peak standard to check for proper performance
Column Compartment: Column oven is cleaned and inspected for proper operation. Temperature test is performed.
Optional valves installed are rebuilt and tested for proper performance.
Listing ID: LA990842
|
|